HydroGeoSphere/Surface Flow (Properties)

From Wikibooks, open books for an open world
Jump to navigation Jump to search

Default surface flow values[edit | edit source]

Unless you modify the default values, all zones (and elements) in the surface flow domain will be assigned the default properties listed in Table 5.18:

Table 5.18: Default Properties for Surface Flow
Parameter Value Unit
Name Surface flow defaults -
X friction factor 0.0548 -
Y friction factor 0.0548 -
Rill storage height 0.0 m
Obstruction storage height 0.0 m
Node coupling scheme shared -
Coupling length 1 × 10−4 m

For each instruction we will again indicate its scope (i.e. .grok, .oprops). Recall that if an instruction is used in the prefix.grok file, it will affect the current set of chosen zones, while in a properties (e.g. .oprops) file, it will only affect the named material of which it is a part.

X friction[edit | edit source]

Scope: .grok .oprops

  1. val x friction factor, in Equation 2.35.
• • •

Y friction[edit | edit source]

Scope: .grok .oprops

  1. val y friction factor, in Equation 2.36.
• • •

Rill storage height[edit | edit source]

Scope: .grok .oprops

  1. val Rill storage height [L], in Section 2.2.2.2.
• • •

Obstruction storage height[edit | edit source]

Scope: .grok .oprops

  1. val Obstruction storage height [L], in Section 2.2.2.2.
• • •

Coupling length[edit | edit source]

Scope: .grok .oprops

  1. val Coupling length [L], in Equation 2.71.
• • •