This page was imported and needs to be de-wikified. Books should use wikilinks rather sparsely, and only to reference technical or esoteric terms that are critical to understanding the content. Most if not all wikilinks should simply be removed. Please remove {{dewikify}} after the page is dewikified. |
Photothermal microspectroscopy (PTMS), alternatively known as photothermal temperature fluctuation (PTTF),[1][2] is derived from two parent instrumental techniques: infrared spectroscopy and atomic force microscopy (AFM). In one particular type of AFM, known as scanning thermal microscopy (SThM), the imaging probe is a sub-miniature temperature sensor, which may be a thermocouple or a resistance thermometer.[3] This same type of detector is employed in a PTMS instrument, enabling it to provide AFM/SThM images: However, the chief additional use of PTMS is to yield infrared spectra from sample regions below a micrometer, as outlined below.
Technique
[edit | edit source]The AFM is interfaced with an infrared spectrometer. For work using Fourier transform infrared spectroscopy (FTIR), the spectrometer is equipped with a conventional black body infrared source. A particular region of the sample may first be chosen on the basis of the image obtained using the AFM imaging mode of operation. Then, when material at this location absorbs the electromagnetic radiation, heat is generated, which diffuses, giving rise to a decaying temperature profile. The thermal probe then detects the photothermal response of this region of the sample. The resultant measured temperature fluctuations provide an interferogram that replaces the interferogram obtained by a conventional FTIR setup, e.g., by direct detection of the radiation transmitted by a sample. The temperature profile can be made sharp by modulating the excitation beam. This results in the generation of thermal waves whose diffusion length is inversely proportional to the root of the modulation frequency. An important advantage of the thermal approach is that it permits to obtain depth-sensitive subsurface information from surface measurement, thanks to the dependence of thermal diffusion length on modulation frequency.
Applications
[edit | edit source]The two particular features of PTMS that have determined its applications so far are:
- spectroscopic mapping may be performed at a spatial resolution well below the diffraction limit of IR radiation, ultimately at a scale of 20-30 nm. In principle, this opens the way to sub-wavelength IR microscopy (see Scanning probe microscopy) where the image contrast is to be determined by the thermal response of individual sample regions to particular spectral wavelengths.
- In general, no special preparation technique is required when solid samples are to be studied. For most standard FTIR methods, this is not the case.
Related technique
[edit | edit source]This spectroscopic technique complements another recently-developed method of chemical characterisation or fingerprinting, namely micro-thermal analysis (micro-TA).[4][5] This also uses an “active” SThM probe, which acts as a heater as well as a thermometer, so as to inject evanescent temperature waves into a sample and to allow sub-surface imaging of polymers and other materials. The sub-surface detail detected corresponds to variations in heat capacity or thermal conductivity. Ramping the temperature of the probe, and thus the temperature of the small sample region in contact with it, allows localized thermal analysis and/or thermomechanometry to be performed.
References
[edit | edit source]- ↑ Hammiche, A. (1999). "Photothermal FT-IR Spectroscopy: A Step Towards FT-IR Microscopy at a Resolution Better Than the Diffraction Limit". Applied Spectroscopy. 53: 810. doi:10.1366/0003702991947379.
{{cite journal}}
:|first2=
missing|last2=
(help);|first3=
missing|last3=
(help);|first4=
missing|last4=
(help);|first5=
missing|last5=
(help);|first6=
missing|last6=
(help) - ↑ H M Pollock and D A Smith (2002). "The use of near-field probes for vibrational spectroscopy and photothermal imaging". In J.M. Chalmers and P.R. Griffiths (ed.). Handbook of vibrational spectroscopy. Vol. 2. John Wiley & Sons. pp. 1472–1492.
- ↑ Majumdar, A. (1999). "Scanning thermal microscopy". Annual Review of Materials Science. 29: 505. doi:10.1146/annurev.matsci.29.1.505.
- ↑ H. M. Pollock and A. Hammiche (2001). "Micro-thermal analysis: techniques and applications". J Phys D. 34: R23-R53. doi:10.1088/0022-3727/34/9/201.
- ↑ J. Ye; et al. (2007). "Scanning thermal probe microscopy: nano thermal analysis with Raman microscopy". Microscopy and Analysis: S5–S8.
{{cite journal}}
: Explicit use of et al. in:|author=
(help)
PTMS in biomedical research and polymer science
[edit | edit source]- F L Martin and H M Pollock (2010). "Microspectroscopy as a tool to discriminate nano-molecular cellular alterations in biomedical research". In A V Narlikar and Y Y Fu (ed.). Oxford Handbook of Nanoscience and Technology vol. 2. pp. 285–336.
- Hammiche, A (2005). "Monitoring Cell Cycle Distributions in MCF-7 Cells Using Near-Field Photothermal Microspectroscopy". Biophysical Journal. 88 (5): 3699. doi:10.1529/biophysj.104.053926. PMC 1305516. PMID 15722424.
{{cite journal}}
:|first2=
missing|last2=
(help);|first3=
missing|last3=
(help);|first4=
missing|last4=
(help);|first5=
missing|last5=
(help) - Grude, Olaug (2007). "Near-field photothermal microspectroscopy for adult stem-cell identification and characterization". Journal of Microscopy. 228 (Pt 3): 366. doi:10.1111/j.1365-2818.2007.01853.x. PMID 18045331.
{{cite journal}}
:|first2=
missing|last2=
(help);|first3=
missing|last3=
(help);|first4=
missing|last4=
(help);|first5=
missing|last5=
(help);|first6=
missing|last6=
(help);|first7=
missing|last7=
(help) - M. J. Walsh; et al. (2008). "FTIR micro-spectroscopy identifies symmetric PO2- modifications as a marker of the putative stem cell region of human intestinal crypts". Stem Cells. 26 (1): 108–118. doi:10.1634/stemcells.2007-0196. PMID 17901405.
{{cite journal}}
: Explicit use of et al. in:|author=
(help) - Grude, O (2009). "Discrimination of human stem cells by photothermal microspectroscopy". Vibrational Spectroscopy. 49: 22. doi:10.1016/j.vibspec.2008.04.008.
{{cite journal}}
:|first2=
missing|last2=
(help);|first3=
missing|last3=
(help);|first4=
missing|last4=
(help);|first5=
missing|last5=
(help);|first6=
missing|last6=
(help);|first7=
missing|last7=
(help);|first8=
missing|last8=
(help) - A Hammiche; et al. (2004). "Mid-infrared micro-spectroscopy of difficult samples using near-field PhotoThermal Micro-Spectroscopy (PTMS)" (PDF). Spectroscopy. 19: 20–42.
{{cite journal}}
: Explicit use of et al. in:|author=
(help), erratum in 19(5), 14 (2004)